As a device that converts mechanical energy into electrical energy, the stable operation of an integrated generator is crucial for ensuring power supply. The following are the key points to pay attention to when maintaining an integrated generator, summarized as follows:
1、 Daily inspection and maintenance of integrated generator
Appearance and connection inspection of integrated generator
Cleaning and Inspection: Regularly clean the surface of the generator, check for cracks, deformations, or damage to the casing, ensure that the ventilation openings are unobstructed, and ensure good heat dissipation.
Tightening of connections: Check if all electrical connections are secure, including cables, wiring terminals, etc., to prevent loose connections from causing poor contact or short circuits.
Oil inspection
Integrated generator oil: Regularly check the oil level and quality to ensure that the oil is sufficient and has not deteriorated. Regularly replace the engine oil and oil filter according to the manufacturer's recommendations.
Coolant: Check the coolant level to ensure that the cooling system is working properly and prevent engine overheating.
Fuel: Ensure that there is sufficient fuel in the fuel tank and regularly check the fuel filter to prevent impurities from blocking the fuel circuit.
Battery Maintenance
Battery level check: Regularly check the battery level to ensure that the battery is in good condition.
Cleaning and fastening: Keep the surface of the battery clean, check if the battery wiring is secure, corrosion-resistant, or loose.
2、 Integrated generator operation monitoring and adjustment
Monitoring of operating parameters
Voltage and frequency: Use a voltmeter and frequency meter to monitor the output voltage and frequency of the generator, ensuring that they are within the normal range.
Temperature and pressure: Monitor the temperature, pressure, and other parameters of the engine and generator to promptly detect and handle any abnormalities.
load regulation
Avoid overload: Allocate loads reasonably according to the rated power of the generator to avoid long-term overload operation.
Load balancing: Ensure three-phase load balancing to prevent damage to the generator caused by overload of one phase.
3、 Regular maintenance of integrated generator
regular maintenance
Replace the integrated generator filter: Regularly replace the air filter, fuel filter, and oil filter to prevent impurities from entering the engine and generator interior.
Check the belt and bearings: Regularly check the tension and wear of the belt, as well as the lubrication and wear of the bearings, and replace damaged components in a timely manner.
4、 Safe operation and storage of integrated generatorssafe operation
Compliance with regulations: Strictly follow the operating procedures and safety regulations of the integrated generator to ensure the personal safety of the operators.
Protective equipment: When operating the generator, it is necessary to wear protective equipment such as safety helmets, protective goggles, protective gloves, etc.
Storage environment
Integrated generator dry and ventilated: The generator should be stored in a dry and well ventilated place to avoid moisture and corrosion.
Keep away from fire sources: The storage location should be kept away from fire sources and flammable and explosive materials to ensure safety.